MerlinGuard Toxic, Combustible & Refrigerant Gas Control Panel
Find Out More
16 Zone gas detection & ventilation control panel with 0-10V output & 4 x 6A relays. Typically used with refrigerant gas detectors.
ParkSafe Gas Detection & Ventilation Control
Find Out More
UL Listed gas detection and ventilation control system developed to help you meet IMC 2021 404.1 requirements for enclosed parking garages. Designed to work with the AGSGM100 gas monitor. 0-10V output & 4 x 6A relays.
GDP2X (8 Detectors)
Find Out More
8 Zone gas detection & emergency shutdown panel which can be used in many applications. Used with the AGSGM100.
GDPX+ (16 Detectors)
Find Out More
16 Zone gas pressure proving, gas detection & emergency shutdown panel which can be used in many applications. Used with the AGSGM100.
GM100 Single or Dual Gas Monitor
Find Out More
- AGS Controls Flagship Detector
- Use as Standalone or with the AGS Sange of Control Panels.
- Compatible with ParkSafe, MerlinGuard, and GDP Panels
- BACnet MS/TP or Modbus RTU
- 2X 4-20mA Outputs
- 1A Dry Contact Relay
Bacnet Refrigerant Leak Detector
Find Out More
- Used for Stand Alone Refrigerant Detection
- BACnet MS/TP or Modbus RTU
- 0-10V Analog Output
- 70mA Dry Contact Relay
- NDIR Refrigerant Sensors
RTFT Refrigerant Leak Detectors
Find Out More
- Used for Refrigerant Detection with MerlinGuard Panel
- Modbus RTU
- 1A Dry Contact Relay
- NDIR Refrigerant Sensors
GM50 Single Gas Detector
Find Out More
- Used for Stand Alone Control of Fans and Valves
- Compressed Gases, Cryogenics, CO2, and Battery Storage
- CO2, O2, and H2 Sensors Available
- Dedicated Repeater Panel
AGS PL4+D Controller
Find Out More
-
DIN-rail mounted gas control panel for small plants
-
Supports up to 12 detectors (4 direct 4–20 mA inputs + 8 via STG/IN8S card)
-
Compatible with flammable, toxic, refrigerant gases and oxygen depletion/enrichment
-
Integrated 5 output relays, expandable up to 32 additional relays (via STG/OUT16S + STG/8REL)
-
Backlit LCD display for gas concentration and alarm setpoints
-
LED indicators for alarm, fault, and power status
-
Internal buzzer for audible alarm and fault conditions
-
Certified SIL1 and ATEX CE 0722 II (2) G [Ex Gb] II
AGS Toxic SMART3G-C2
Find Out More
- Explosion-proof design for hazardous environments
- Certified for ATEX Zone 1 and, with dust adapter, Zone 21
- Rugged aluminum enclosure with stainless steel sensor head
- Electrochemical cell for accurate toxic gas detection
- Power supply: 12–24 VDC
- Standard 4–20 mA output
- Optional RS485 communication and relay modules
- ATEX & IECEx certified, rated IP65
- Meets SIL2/SIL3 safety standards for safety-critical systems
AGS Flammable SMART3G-C2
Find Out More
- Explosion-proof industrial gas detector for ATEX Zone 1 (or Zone 21 with dust adapter)
- Stainless steel sensor head: Type 2 (40 mm) or Type 3 (48 mm)
- Pellistor sensors for fast, accurate flammable gas detection up to 100% LEL
- Power: 12–24 VDC, standard 4–20 mA output
- Optional RS485 communication and 1 or 3 relays
- Rugged aluminum enclosure, IP65 rated
- Certified ATEX & IECEx, SIL2/SIL3 ready for safety-critical systems
AGS Infrared Cells SMART3G-C3
Find Out More
- Explosion-proof industrial gas detector
- Suitable for Class I, Division 2 and, with dust adapter, Class II, Division 2
- Stainless steel sensor head, 40 mm diameter
- Electrochemical cell for accurate toxic gas detection
- Power supply: 12–24 VDC
- Standard 4–20 mA 3-wire output
- Optional RS485 communication and 1 or 3 relays
- Compact enclosure: 106 × 160 × 62 mm
- Single M20 cable gland on top
AGS Electrochemical Cells SMART3G-C3
Find Out More
- Explosion-proof industrial gas detector for Class I, Division 2 (or Class II, Division 2 with dust adapter)
- Stainless steel sensor head, 40 mm diameter
- Electrochemical cell for reliable toxic gas detection
- Power: 12–24 VDC, standard 4–20 mA output
- Optional RS485 communication and 1 or 3 relays
- Compact enclosure: 106 × 160 × 62 mm, with M20 cable gland
AGS SMART3R
Gas Detector
Find Out More
- Gas detector for non-classified areas like machinery rooms and laboratories
- Electrochemical cell for accurate toxic gas detection
- 4 LED status indicators with internal buzzer for alarm/fault
- Power: 12–24 VDC (optional 120 VAC version)
- Outputs: 3 relays, RS485 communication, 4–20 mA analogue (not on 120 VAC version)
- Polycarbonate enclosure: 130 × 130 × 74 mm
- Cable entries: 2 × M20, expandable to 6 × M16
- Optional remote sensor head via RJ12 connection